Model: XMT-708 Series
merk: CJ
Plaats Van Herkomst: China
Verkoopeenheden | : | Piece/Pieces |
Ⅰ belangrijkste technische specificatie
L -meetafwijking: ≤ ± 0,5%f · s ± 1
l koud uiteinde compenserende afwijking: ≤ ± 2,0 ℃
L bemonsteringscyclus: 0,5s
L Besturingscyclus: relaisuitgang 2 ~ 120S, andere is 2s.
l Relaisuitgang Contactcapaciteit: AC220V/7A (weerstandsbelasting)
L vermogen: AC85V ~ 242V, 50/60Hz
L Werkconditie: Temperatuur 0 ~ 50,0 ℃, Relatieve vochtigheid <85%RV, zonder corrode en sterke elektrische straling.
Ⅱ Code -instellingsmodus
Series |
Code |
Name |
Setting range |
Manual |
Remarks |
0 |
SP |
Fixed value |
Determined by P-SL P-SH |
- |
50.0 |
1 |
AL-1 |
Alarm 1 |
Determined by P-SL,P-SH when the upper and lower limit range,it is0~50.0 when the upper and lower limit deviation alarm |
Alarm 1 setting value |
10 |
2 |
AL-2 |
Alarm 2 |
Determined by P-SL,P-SH when the upper and lower limit range,it is0~50.0 when the upper and lower limit deviation alarm |
Alarm 1 setting value |
10 |
3 |
P |
Proportion modulus |
0~100 |
When the P↑,the the proportion function↓ When P=0,the meter is ON/OFF control |
8 |
4 |
I |
Calculus time |
0~2000S |
240 |
|
5 |
d |
differential time |
0~200S |
30 |
|
6 |
At |
Setting itself |
ON:open setting inself function OFF:close setting itself function |
Select of setting itself |
OFF |
7 |
t |
SSR proportion Control period |
1~120S |
the movements cycle ON/OFF of Setting relays control is no meaning |
20 |
8 |
Hy |
Main control by drop in level |
0.1~50.0 |
Only have meaning when main control output is ON/OFF(P=0) |
1.0 |
9 |
Hy-1 |
Alarm 1 drop in level |
0.1~50.0 |
It has use dropin level setting of alarm contact output |
1.0 |
10 |
Hy-2 |
Alarm 2 drop in level |
0.1~50.0 |
It has use dropin level setting of alarm contact output |
1.0 |
11 |
Pb |
Sensor error amendment |
±20.0 |
The sensor have deviation can use item to revisal |
0 |
12 |
FILT |
Filt modulus |
0~50 |
Is the software filter constants of measurement sampling.The constant ↑,the Measurements antijamming capabilityMeasurements antijamming capability↑,but the measurement and system time ↓ |
20 |
13 |
dp |
Show accuracy |
0~1 |
0: have radix point,1: have no radix point |
- |
14 |
P-SH |
Display the high limit |
P-SL~9999 |
Can set the high limit displaying input signal |
400 |
15 |
P-SL |
Display the low limit |
-1999~P-SH |
Can set the low limit displaying input signal |
0 |
16 |
OUTH |
Allow exports max value |
OUTL~200 |
It will no role when highest outputlimit,,manual and position. |
200.0 |
17 |
OUTL |
Allow exports min value |
0.0~OUTH |
It will no role when lowest outputlimit,,manual and position. |
0.0 |
18 |
ALP1 |
Alarm1 and output definition |
0~4 |
‘o’:indicate no alarm ‘1’:upper limit touch alarm ‘2’:lower limit touch alarm ‘3’:upper windage alarm ‘4’:lower windage alarm |
- |
19 |
ALP2 |
Alarm2 and output definition |
0~4 |
‘o’:indicate no alarm‘1’:upper limit touch alarm‘2’:lower limit touch alarm‘3’:upper windage alarm‘4’:lower windage alarm |
- |
20 |
COOL |
System function choice |
0~1 |
‘0’:reverse control ‘1’:positive control |
0 |
21 |
OPPO |
Open power output |
0~100 |
Soft start functionthat meters coefficient after first export of electric power |
0 |
22 |
LOCK |
Code lock |
0~50 |
0- all the parameter can be revised 1- only the sp can be revised |
0 |
23 |
Sn |
Input type |
0~7 |
0-CU50 (-50.0~150.0℃) ;1-PT1 (-200.0~200.0℃) ;2-PT2 (-200.0~600.0℃) ;3-K (0~1300℃) ;4-E (0~700.0℃) ;5-J (0~900.0℃) ;6-T (-200~400.0℃) ;7-S (0~1600℃) ;
|
|
24 |
OP-A |
Output type |
1~4 |
1- RLP SSR output mode 2- SSR solid state relay 3- Zero controllable silicon contact signal when it exceed zero output mode 4- Mut controllable silicon phase trigger contact output mode 5- 0~10MA linearity control electric current output 6- 4~20MA linearity control electric current output
|
Ⅲ Technische indexen
1 、 Het parameterinstellingsgebied
Druk op de set -toets 3s Voer in het eerste instellingsgebied in, de meter geeft de parametercode 1 ~ 24 in het venster op de bovenste rij weer en toont de parametergegevens op de lage rij. Druk in deze tijd op de ▲ 、 ▼ of t -toets om de parameter aan te passen en druk vervolgens op de set -toets om te behouden. Druk op de set -toets lange tijd zal terugtrekken of druk op de set + ƒ Toets wordt rechtstreeks ingetrokken. Als binnen 10 seconden niet op elke toets drukken, wordt deze automatisch om de gegevens te bewaren en de instelling in te trekken.
2 、 Het instellingsgebied met vaste waarde
Wanneer de meter is ingesteld met de elektriciteit, drukt u op de set -toets eenmaal in het instellingsgebied, kunt u de parameter van "SP" instellen.
3 、 Handmatige verordening
Wanneer de meter is ingesteld met de elektriciteit, drukt u op de T -toets ongeveer 3s in de handmatige verordening, deze wordt "H" weergegeven op de onderste rij, in deze tijd kan het uitgangsvermogen instellen; Druk opnieuw op de T -toets ongeveer 3s, deze zal de handmatige verordening intrekken.
Ⅳ Zelf instellen
Het gebruik van de meter in de eerste keer of de omgeving heeft een wisselaar, het vinden van controle niet goed, in deze tijd moet u de instelling zelf gebruiken. Bijvoorbeeld:
De eerste set de At = 1, ben licht flikkerd, de meter invoert in de instelling zelf, druk op de set -toets Voer in de parameterinstelling in. Set De HY is 0,5 ~ 1 ℃, als de uitgang relais is Set de t = 2s, heeft de meter driemaal trillen, automatisch bewaarde P, I, D -parameter en de AM Light Off, de instelling zelf afwerking.
Ⅴ Verbindingsschema (consult)
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.